SuperLogic 2500 Manual
Low Pressure Switch Test
While the system is running, shut o the water supply to the system. The system should shut o . If the system does not shut o a er
ten seconds, either unplug the system or restore the water supply to the system. Call HydroLogic to diagnose problem.
DO NOT LET THE SYSTEM RUN WITHOUT THE WATER SUPPLY TURNED ON. PUMP DAMAGE WILL OCCUR.
Tank ConnecƟ on
Make the tank connec on as outlined on page 8.
OpƟ onal Float Switch Test (for non-pressurized tanks)
The system should run when the oat is hanging down by the power cord. Tilt oat up so the power cord is at the bo om of the
oat. The unit should shut o . If unit does not shut o , re-check installa on procedure.
OperaƟ on and Maintenance
SuperLogic 2500 systems are designed for simple opera on with li le user interven on. We recommend keeping accurate
performance records and following a regular preventa ve maintenance schedule to maximize the life of your system.
Daily System Checks
Your water supply pressure can vary from me to me. This can also a ect your system opera ng pressure. Check
and adjust your vessel pressure daily to ensure maximum water produc on rates and quality. Check both the pre lter in pressure
gauge and pre lter out pressure gauge. Under normal condi ons, there should be a 3-5 psi di erence
between the two gauges. When the di erence reaches 10 psi it is recommended to change your pre- lters.
Monthly System Checks
In addi on to the daily checks, it is recommended to repeat the procedure in the sec on on Performance Veri ca on
and record all data on a performance record sheet.
Semi-Annual Service
It is recommended to change both sediment and carbon lter cartridges at least every six months. Carbon cartridges
should be changed more o en if bad taste and/or odor becomes evident. Sediment cartridge should be changed more o en if water
supply pressure and lter pressure gauges di er by 10 psi or more.
Peripheral Equipment
Peripheral equipment such as tanks also have periodic maintenance requirements. It is essen al to maintain these as they can have a
drama c e ect on the performance of your system. Refer to their speci c manuals for proper maintenance procedures.