Installation & Maintenance Manual

Strona 2

Tested @ 77F and 500 PPM source water. Flow rates will vary depending on source water, temperature and PPM’s.IMPORTANT NOTE:The flow rate of product wa

Strona 3 - SAFETY GUIDES

TO CARE FOR THE RO SYSTEMThe components of the RO system are designed to function with minimal maintenance. However, the membrane elements and pre-filt

Strona 4 - SILICONELUBRICANT

If changing membrane elements:7. Remove membrane sumps. Remove and discard used a. elements.Remove new elements from packaging.b. CAUTION: Elements

Strona 5

Performance SpecificationsMinimum and Maximum Operating ConditionsCondition Minimum MaximumInlet Pressure 40 psi (2.76 bar) 80 psi (5.52 bar)

Strona 6

TROUBLESHOOTINGIssue Possible Cause Corrective ActionLow product flow rateLow driving pressure.Increase feed pressure. Consider pump for low pressure l

Strona 7 - INSTALLATION

NOTES:________________________________________________________________________________________________________________________________________________

Strona 9

NOTES:________________________________________________________________________________________________________________________________________________

Strona 10 - IMPORTANT NOTE:

EVOLUTION-RO1000 Reverse Osmosis SystemInstallation and Maintenance ManualSAFETY GUIDES Read and follow all steps and guides carefully before installi

Strona 11 - REPLACEMENT OF PRE-FILTER

THE BASIC REVERSE OSMOSIS SYSTEM cont.COMPLETEMANIFOLDPN 23062 (1 pc)SUPPORTLEG/SUMP WRENCHPN 23063 (1 pc)SUMP(FILTERHOUSING)& O-RINGSUMPPN 23115

Strona 12 - CAUTION:

LOCATION OF SYSTEMThe reverse osmosis system can be installed under or near a sink or any other water supply. The RO assembly can be placed on the sin

Strona 13

THE BASIC REVERSE OSMOSIS SYSTEM cont.1.5" Air Gap RequiredInlet-1/2" WhiteDrain - 3/8" Black Purified Water - 3/8" BlueFeed Water

Strona 14 - TROUBLESHOOTING

INSTALLATION STEP 1: Install cold water supply fitting. Use either the included garden hose connector or any of the other optional feed fittings. STEP

Strona 15

NOTE: Make sure the tubing is pushed past the O-rings for a secure fit. Also, when replacing any tubing, cut tubing back ~1/4

Strona 16 - GL4000442 RevA

Recommended Placement PositionsThe RO assembly should be positioned in one of two ways. The first position is with the unit standing upright using the